GLOBALTEK ENGINEERING KNOWLEDGE HUB · ACTIVITY 14

Fire & Life Safety Coordination

Fire and life-safety systems work as an integrated strategy of detection, alarm, suppression, compartmentation, smoke control, emergency power/lighting and safe egress. Modifications to one element can invalidate another.

37 technical visuals6 execution stages24 technical chaptersQA/QC + failures + maintenance
Fire & Life Safety Coordination technical hero
GUIDE MAP

Read the discipline visually, then go into the engineering detail.

Every image below is activity-specific. No repeated generic placeholder sheets are used in this guide.

01 · SYSTEM OVERVIEW

What this activity is

Fire & Life Safety Coordination overview drawing

What this activity is

Fire and life-safety coordination ensures the fit-out does not compromise the building’s approved fire strategy. It includes active systems such as alarm and sprinkler interfaces plus passive measures such as rated partitions, doors, firestopping and protected escape routes.

What to expect

Expect life-safety requirements to influence layouts from the start. Moving a partition can change sprinkler coverage, detector spacing, exit travel, fire-rated construction and emergency signage. Required authority approvals and inspections should be identified before work begins.

01Start from the approved fire strategy and cause/effect matrix
02Coordinate sprinkler/detector coverage with ceilings and obstructions
03Preserve rated walls/floors at every penetration
04Use listed/approved firestop systems matching the actual substrate and service
05Test interfaces and cause/effect sequences
06Close authority inspections with complete records and labels
02 · ENGINEERING FUNDAMENTALS

Understand why the system behaves the way it does.

01

Sprinkler hydraulic calculations use design density/area and network losses; use the approved specialist design and code

02

Battery/standby capacity must be calculated for the fire alarm/emergency system duty cycle

03

Fire resistance is an assembly property—substituting board, framing, sealant or penetration detail can change the rating

Fire & Life Safety Coordination engineering fundamentals
01

Passive fire protection is easy to damage during MEP changes. Every cable/pipe/duct penetration through a rated barrier needs a compatible tested firestop configuration and documented inspection.

02

Detector and sprinkler locations must be coordinated with ceiling geometry, bulkheads, diffusers and obstructions; “moving it to look symmetrical” may affect compliance.

03

Cause-and-effect testing should verify the complete sequence: alarm, HVAC shutdown/smoke control, doors, lifts, suppression interfaces, notification and monitoring as applicable.

03 · EXECUTION WORKFLOW

Six progressive stages from preparation to verified handover.

Open any plate to read the full-resolution technical notes.

Fire Strategy Design Basis technical drawing
STAGE 01

Fire Strategy Design Basis

Confirm occupancy, exits, rated elements and affected systems

Engineering intent

Maintain complete tested construction from structure to structure / approved termination

Inspection / hold point

Life-safety drawings match current layout

Best practice

Coordinate life-safety before ceiling design is frozen

Failure to avoid

Moving partitions without revising fire-device coverage

Handover / maintenance

Maintain alarm / sprinkler / emergency systems through authorised service programmes

Coordination Layouts technical drawing
STAGE 02

Coordination Layouts

Overlay ceilings, partitions, MEP and fire-system devices

Engineering intent

Use tested firestop compatible with service, opening, substrate and required rating

Inspection / hold point

Rated walls / doors / seals are complete and traceable

Best practice

Use tested systems rather than site-invented firestop combinations

Failure to avoid

Cutting openings in rated walls and sealing with ordinary foam / mortar

Handover / maintenance

Inspect fire doors, closers, seals and latching routinely

First Fix Firestopping technical drawing
STAGE 03

First Fix Firestopping

Install approved alarm / sprinkler / suppression changes by qualified party

Engineering intent

Frame, leaf, hardware, closer, seals and glazing must form an approved rated assembly where required

Inspection / hold point

Sprinkler / detector / emergency-light coverage is unobstructed

Best practice

Photograph / record concealed firestopping before closure

Failure to avoid

Using non-compliant decorative finishes in regulated locations

Handover / maintenance

Do not drill rated walls / shafts without approved firestop reinstatement

Final Devices technical drawing
STAGE 04

Final Devices

Complete rated walls, doors and penetration seals before finishes conceal interfaces

Engineering intent

Coordinate ceiling / soffit / feature elements so coverage is not obstructed

Inspection / hold point

Firestops are tested systems installed correctly

Best practice

Protect fire-rated doors from unauthorized hardware modifications

Failure to avoid

Obstructing sprinklers with bulkheads or joinery

Handover / maintenance

Keep exits, signage and access to fire equipment unobstructed

Integrated Testing technical drawing
STAGE 05

Integrated Testing

Conduct alarm, sprinkler / pump interfaces, emergency lighting and door checks as required

Engineering intent

Coordinate with ceiling features and approved design spacing

Inspection / hold point

Egress routes and signage are compliant / clear

Best practice

Keep egress routes free during construction as well as at handover

Failure to avoid

Disabling / covering detectors during work without controlled reinstatement

Handover / maintenance

Record future alterations that affect the approved fire strategy

Approval Handover technical drawing
STAGE 06

Approval Handover

Complete internal pre-inspection, authority / consultant inspection and archive certificates

Engineering intent

Keep routes, exits and required widths unobstructed

Inspection / hold point

Required tests and authority / consultant inspections are closed

Best practice

Conduct internal pre-inspection using the authority checklist

Failure to avoid

Requesting inspection before internal life-safety checks are complete

Handover / maintenance

Retain certificates / test results for audits and authority inspections

04 · TECHNICAL CHAPTERS

24 detailed sub-activities for Fire & Life Safety Coordination.

The file naming and page mapping are one-to-one: each technical subject has its own individual high-resolution image.

Compartmentation
TECHNICAL CHAPTER 01

Compartmentation

Compartmentation: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for compartmentation before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Life-safety drawings match current layout

Failure to avoid

Moving partitions without revising fire-device coverage

Maintenance / long-term performance

Maintain alarm / sprinkler / emergency systems through authorised service programmes

Fire Rated Doors
TECHNICAL CHAPTER 02

Fire Rated Doors

Fire Rated Doors: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for fire rated doors before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Rated walls / doors / seals are complete and traceable

Failure to avoid

Cutting openings in rated walls and sealing with ordinary foam / mortar

Maintenance / long-term performance

Inspect fire doors, closers, seals and latching routinely

Firestopping Penetrations
TECHNICAL CHAPTER 03

Firestopping Penetrations

Firestopping Penetrations: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for firestopping penetrations before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Sprinkler / detector / emergency-light coverage is unobstructed

Failure to avoid

Using non-compliant decorative finishes in regulated locations

Maintenance / long-term performance

Do not drill rated walls / shafts without approved firestop reinstatement

Fire Alarm Panel Network
TECHNICAL CHAPTER 04

Fire Alarm Panel Network

Fire Alarm Panel Network: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for fire alarm panel network before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Firestops are tested systems installed correctly

Failure to avoid

Obstructing sprinklers with bulkheads or joinery

Maintenance / long-term performance

Keep exits, signage and access to fire equipment unobstructed

Detectors
TECHNICAL CHAPTER 05

Detectors

Detectors: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for detectors before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Egress routes and signage are compliant / clear

Failure to avoid

Disabling / covering detectors during work without controlled reinstatement

Maintenance / long-term performance

Record future alterations that affect the approved fire strategy

Mcp Sounders Strobes
TECHNICAL CHAPTER 06

Mcp Sounders Strobes

Mcp Sounders Strobes: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for mcp sounders strobes before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Required tests and authority / consultant inspections are closed

Failure to avoid

Requesting inspection before internal life-safety checks are complete

Maintenance / long-term performance

Retain certificates / test results for audits and authority inspections

Sprinklers
TECHNICAL CHAPTER 07

Sprinklers

Sprinklers: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for sprinklers before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Life-safety drawings match current layout

Failure to avoid

Moving partitions without revising fire-device coverage

Maintenance / long-term performance

Maintain alarm / sprinkler / emergency systems through authorised service programmes

Fire Pumps
TECHNICAL CHAPTER 08

Fire Pumps

Fire Pumps: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for fire pumps before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Rated walls / doors / seals are complete and traceable

Failure to avoid

Cutting openings in rated walls and sealing with ordinary foam / mortar

Maintenance / long-term performance

Inspect fire doors, closers, seals and latching routinely

Hydrants Hose Reels
TECHNICAL CHAPTER 09

Hydrants Hose Reels

Hydrants Hose Reels: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for hydrants hose reels before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Sprinkler / detector / emergency-light coverage is unobstructed

Failure to avoid

Using non-compliant decorative finishes in regulated locations

Maintenance / long-term performance

Do not drill rated walls / shafts without approved firestop reinstatement

Extinguishers
TECHNICAL CHAPTER 10

Extinguishers

Extinguishers: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for extinguishers before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Firestops are tested systems installed correctly

Failure to avoid

Obstructing sprinklers with bulkheads or joinery

Maintenance / long-term performance

Keep exits, signage and access to fire equipment unobstructed

Smoke Extract
TECHNICAL CHAPTER 11

Smoke Extract

Smoke Extract: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for smoke extract before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Egress routes and signage are compliant / clear

Failure to avoid

Disabling / covering detectors during work without controlled reinstatement

Maintenance / long-term performance

Record future alterations that affect the approved fire strategy

Stair Lobby Pressurisation
TECHNICAL CHAPTER 12

Stair Lobby Pressurisation

Stair Lobby Pressurisation: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for stair lobby pressurisation before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Required tests and authority / consultant inspections are closed

Failure to avoid

Requesting inspection before internal life-safety checks are complete

Maintenance / long-term performance

Retain certificates / test results for audits and authority inspections

Fire Smoke Dampers
TECHNICAL CHAPTER 13

Fire Smoke Dampers

Fire Smoke Dampers: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for fire smoke dampers before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Life-safety drawings match current layout

Failure to avoid

Moving partitions without revising fire-device coverage

Maintenance / long-term performance

Maintain alarm / sprinkler / emergency systems through authorised service programmes

Means Egress
TECHNICAL CHAPTER 14

Means Egress

Means Egress: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for means egress before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Rated walls / doors / seals are complete and traceable

Failure to avoid

Cutting openings in rated walls and sealing with ordinary foam / mortar

Maintenance / long-term performance

Inspect fire doors, closers, seals and latching routinely

Emergency Lighting
TECHNICAL CHAPTER 15

Emergency Lighting

Emergency Lighting: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for emergency lighting before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Sprinkler / detector / emergency-light coverage is unobstructed

Failure to avoid

Using non-compliant decorative finishes in regulated locations

Maintenance / long-term performance

Do not drill rated walls / shafts without approved firestop reinstatement

Kitchen Suppression
TECHNICAL CHAPTER 16

Kitchen Suppression

Kitchen Suppression: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for kitchen suppression before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Firestops are tested systems installed correctly

Failure to avoid

Obstructing sprinklers with bulkheads or joinery

Maintenance / long-term performance

Keep exits, signage and access to fire equipment unobstructed

Cause Effect
TECHNICAL CHAPTER 17

Cause Effect

Cause Effect: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for cause effect before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Egress routes and signage are compliant / clear

Failure to avoid

Disabling / covering detectors during work without controlled reinstatement

Maintenance / long-term performance

Record future alterations that affect the approved fire strategy

Zoning Addressing
TECHNICAL CHAPTER 18

Zoning Addressing

Zoning Addressing: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for zoning addressing before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Required tests and authority / consultant inspections are closed

Failure to avoid

Requesting inspection before internal life-safety checks are complete

Maintenance / long-term performance

Retain certificates / test results for audits and authority inspections

Emergency Power
TECHNICAL CHAPTER 19

Emergency Power

Emergency Power: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for emergency power before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Life-safety drawings match current layout

Failure to avoid

Moving partitions without revising fire-device coverage

Maintenance / long-term performance

Maintain alarm / sprinkler / emergency systems through authorised service programmes

Accessibility Life Safety
TECHNICAL CHAPTER 20

Accessibility Life Safety

Accessibility Life Safety: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for accessibility life safety before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Rated walls / doors / seals are complete and traceable

Failure to avoid

Cutting openings in rated walls and sealing with ordinary foam / mortar

Maintenance / long-term performance

Inspect fire doors, closers, seals and latching routinely

Authority Inspection
TECHNICAL CHAPTER 21

Authority Inspection

Authority Inspection: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for authority inspection before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Sprinkler / detector / emergency-light coverage is unobstructed

Failure to avoid

Using non-compliant decorative finishes in regulated locations

Maintenance / long-term performance

Do not drill rated walls / shafts without approved firestop reinstatement

Integrated Testing
TECHNICAL CHAPTER 22

Integrated Testing

Integrated Testing: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for integrated testing before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Firestops are tested systems installed correctly

Failure to avoid

Obstructing sprinklers with bulkheads or joinery

Maintenance / long-term performance

Keep exits, signage and access to fire equipment unobstructed

Firestop Register
TECHNICAL CHAPTER 23

Firestop Register

Firestop Register: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for firestop register before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Egress routes and signage are compliant / clear

Failure to avoid

Disabling / covering detectors during work without controlled reinstatement

Maintenance / long-term performance

Record future alterations that affect the approved fire strategy

Fire Command Monitoring
TECHNICAL CHAPTER 24

Fire Command Monitoring

Fire Command Monitoring: Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Design intent

Define the performance and construction intent for fire command monitoring before fabrication or installation. Read the drawing together with the approved project specification, manufacturer data and adjoining details.

Coordination

Coordinate compartmentation, detection/alarm, suppression, smoke control, egress, emergency power/lighting, cause-and-effect, firestopping, testing and Civil Defence approval interfaces.

Inspection / QA

Required tests and authority / consultant inspections are closed

Failure to avoid

Requesting inspection before internal life-safety checks are complete

Maintenance / long-term performance

Retain certificates / test results for audits and authority inspections

05 · QA/QC

Inspect before concealment and before handover.

Fire & Life Safety Coordination QA QC
01Life-safety drawings match current layout
02Rated walls / doors / seals are complete and traceable
03Sprinkler / detector / emergency-light coverage is unobstructed
04Firestops are tested systems installed correctly
05Egress routes and signage are compliant / clear
06Required tests and authority / consultant inspections are closed
06 · COMMON FAILURES

Recognise the failure mechanism—not only the visible defect.

Failures to avoid

×Moving partitions without revising fire-device coverage

×Cutting openings in rated walls and sealing with ordinary foam / mortar

×Using non-compliant decorative finishes in regulated locations

×Obstructing sprinklers with bulkheads or joinery

×Disabling / covering detectors during work without controlled reinstatement

×Requesting inspection before internal life-safety checks are complete

Fire & Life Safety Coordination common failures
07 · MAINTENANCE & AFTERCARE

Design for access, repair and long-term performance.

Fire & Life Safety Coordination maintenance

Maintenance controls

✓Maintain alarm / sprinkler / emergency systems through authorised service programmes

✓Inspect fire doors, closers, seals and latching routinely

✓Do not drill rated walls / shafts without approved firestop reinstatement

✓Keep exits, signage and access to fire equipment unobstructed

✓Record future alterations that affect the approved fire strategy

✓Retain certificates / test results for audits and authority inspections

08 · STANDARDS & MANUFACTURER REFERENCES

Use the latest approved project documents and tested systems.

• Latest UAE Fire and Life Safety Code and current Civil Defence requirements

• Approved building fire strategy / life-safety drawings

• Relevant NFPA standards where referenced / adopted by the project authority

• Tested fire-rated assembly / firestop manufacturer documentation

• Approved fire-alarm / sprinkler specialist design and cause-and-effect where applicable

• Authority inspection and completion requirements

Fire & Life Safety Coordination standards and brands
Technical guidance is educational and indicative. Final design, dimensions, materials, installation details and acceptance criteria must follow the approved project documents, manufacturer instructions and the latest requirements of the relevant UAE authority, landlord, consultant and specialist engineer.